Hint:

Standard voltage: 11 to 14 v
If the voltage is below 11 v, recharge or replace the battery before proceeding.

Result 

Result 


End
System description
InitializationEvaporator temperatur sensor
Removal
Remove air conditioning unit
Remove the air conditioning radiator (see page ac-
185).
Remove evaporator temperature sensor
(see page ac-193)
Inspection
Inspect evaporator temperature sensor
Measure the resistance of the sensor.
Standard resistance
No ...
Valve body
Components
Disassembly
Remove shift solenoid valve slt
Remove the bolt, plate and shift solenoid valve slt
from the valve body.
Remove shift solenoid valve sl1
Remove the bolt, plate and shift solenoid valve sl1
from the valve body.
Remove shift solenoid ...
Inspection
Inspect cylinder block for warpage
Using a precision straightedge and feeler gauge,
measure the warpage of the surface that is in
contact with the cylinder head gasket.
Maximum warpage:
0.05 Mm (0.0020 In.)
If the warpage is greater than the maximum, replace
the cylinder block ...