Toyota RAV4 (XA40) 2013-2018 Service Manual: How to proceed with troubleshooting (2006/01- )
Hint:
- Use these procedures to troubleshoot the air conditioning
system.
- *: Use the intelligent tester.
- Vehicle brought to workshop

- Customer problem analysis and symptom check

- Inspect battery voltage
Standard voltage:
11 to 14 v
If the voltage is below 11 v, recharge or replace the battery
before proceeding.

- Check can communication system*
- Use the intelligent tester to check if the can
communication system is functioning.
Result

- Check dtc or check sensor check code through panel diagnosis*
- Check dtcs or sensor check codes.
- Write down the dtcs or sensor check codes.
- Clear the dtcs or sensor check codes.
- Check whether the dtcs or sensor check codes recur.
- Reproduce the problem symptoms in accordance
with the dtcs or sensor check codes that were
written down, and check whether the dtcs or
sensor check codes recur.
Hint:
Refer to the dtc chart when any dtcs or sensor
check codes are output.
Result 

- Refer to problem symptoms table
Result

- Overall analysis and troubleshooting*
- Data list / active test (see page ac-37)
- Panel diagnosis (indicator check) (see page ac-31)
- Panel diagnosis (sensor check) (see page ac-31)
- Panel diagnosis (actuator check) (see page ac-31)
- Terminals of ecu (see page ac-27)
- Adjust, repair or replace
- Confirmation test
End
Hint:
Use these procedures to troubleshoot the air conditioning
system.
*: Use the intelligent tester.
Vehicle brought to workshop
Customer problem analysis and symptom check
...
Hint:
The following items can be customized.
Notice:
When the customer requests a change in a function,
first make sure that the function can be customized.
Be sure to make a note of the cur ...
Other materials:
Fuel tank cap
Inspection
Inspect fuel tank cap assembly
Visually check that the cap and gasket are not
deformed or damaged.
If the result is not as specified, replace the cap
assembly or gasket.
Remove the gasket from the exhaust manifold.
...
Blower motor circuit
Description
When the heater control (blower switch) is set to position 1 or higher, the
contact of the htr relay is
closed, current flows to the blower motor, and the blower motor operates. The
blower motor speed can be
changed by exchanging the ground and the blower resistor circuit with the ...
Removal
Disconnect cable from negative battery
terminal
Caution:
Wait at least 90 seconds after disconnecting the
cable from the negative (-) battery terminal to
prevent airbag and seat belt pretensioner activation.
Remove steering column cover lower
Detach the 4 claws, release the ...