Hint:

Standard voltage: 11 to 14 v
If the voltage is below 11 v, recharge or replace the battery before proceeding.






End
System description
Operation checkData list / active test
Read data list
Hint:
Using the intelligent tester's data list allows switch,
sensor, actuator, and other item values to be read
without removing any parts. Reading the data list
early in troubleshooting is one way to save time.
Notice:
In the table below, the values listed under "no ...
Check mode procedure
Description
Check mode has a higher sensitivity to malfunctions
and can detect malfunctions that normal mode
cannot detect. Check mode can also detect all the
malfunctions that normal mode can detect. In check
mode, dtcs are detected with 1 trip detection logic.
Check mode pro ...
Inspection
Inspect generator brush holder assembly
Using a vernier caliper, measure the brush length.
Standard length:
9.5 To 11.5 Mm (0.374 To 0.453 In.)
Minimum length:
4.5 Mm (0.177 In.)
If the brush length is less than the minimum, replace
the generator brush holder assembly.
Inspe ...