Disassembly
Remove no. 1 Side defroster nozzle duct
Remove the 3 screws and duct.
Remove no. 2 Side defroster nozzle duct
Remove the 3 screws and duct.
Remove no. 1 Heater to register duct
Remove the screw and duct.
Remove no. 2 Heater to register duct
...
Inspection
Inspect generator brush holder assembly
Using a vernier caliper, measure the brush length.
Standard length:
9.5 To 11.5 Mm (0.374 To 0.453 In.)
Minimum length:
4.5 Mm (0.177 In.)
If the brush length is less than the minimum, replace
the generator brush holder assembly.